5 Commits
Author SHA1 Message Date
Julien LutranandClaude Opus 5 81d22c5daf nas+nuc: cold boot verified; record what clearing the metadata errors took
Both hosts were powered off and brought back from a cold start, which is
the first real test of everything built on 2026-08-30.

nas: both pools imported from /etc/zfs/zpool.cache, all instances
autostarted, NFS exports republished, 0 failed units. nuc: /dev/dri
present with 0 i915 warnings (booted with the display unplugged), NFS
auto-remounted, VAAPI transcode at 9.5x realtime.

Records the ordering that actually cleared tank's inherited
<metadata>:<0x0> and <0x3d>: a scrub alone found 0 errors and repaired 0B
but left them, and a plain `zpool clear` afterwards did not drop them —
ZFS flushes the persistent error log on a scrub run *after* the clear.
That matters beyond tidiness, because while those entries stand
`zpool status -x` reports the pool unhealthy forever and zpool-health.sh
cannot signal anything new.

Two kiosk corrections, both from observed behaviour:

- the Pioneer DAC being switched off is the most likely cause of
  "video, no sound" — asound.conf pins the ALSA default to it by card
  name, so `default` fails to open outright and mpv falls back to null
  silently. Adds the one-line aplay check.
- hotplugging the display makes cage exit once and Restart=on-failure
  recovers it ~5s later. Do NOT restart it by hand; check
  ActiveEnterTimestamp against the hotplug time first.

Also flags that the OS mirror is still untested with a disk physically
unplugged — it is a guess until then.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-31 10:16:44 +02:00
Julien LutranandClaude Opus 5 203728674f nuc: media over NFS from nas, on-demand role, i915 and input traps
nuc keeps only what needs its iGPU. blocky, privoxy and transmission-bt
moved to nas so the box can be powered off when not watching Jellyfin or
using the Spotify kiosk.

- /srv/media is now an NFSv4 mount from nas; jellyfin-server reads it
  with shift=false (idmapped mounts are unsupported on NFS, as the
  container doc already noted for CIFS) and readonly=true
- replication to nas is a systemd timer with Persistent=true, not cron —
  an on-demand host misses its 03:30 window and cron cannot catch up

Two failures documented in full, both diagnosed from the wrong layer
first:

- booting with the TV connected and powered on kills the i915 probe
  (drm_WARN_ON in intel_modeset_setup_hw_state), so /dev/dri never
  appears, snd_hda_intel deferred-probes forever holding the PCI device
  lock, and incusd blocks in sriov_numvfs_show — no container starts at
  all, including LAN DNS. Identical on 6.12.107 and 6.12.105.
- the kiosk input gid mismatch is real but was NOT the cause of the
  2026-08-30 outage (flat K400 batteries were); seatd opens input devices
  as root, so kiosk group membership is not on that path. Records the
  one-line raw capture that settles hardware-vs-software immediately.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-30 23:53:30 +02:00
Julien LutranandClaude Opus 4.8 43ef0e5447 nuc/jellyfin-client: document host-side input hotplug auto-recovery
Add udev rule + oneshot service + script on nuc that restart the
container kiosk when the Logitech Unifying receiver is replugged, since
hotplug uevents don't cross into the container's netns and cage only
enumerates input at startup.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-08-11 01:39:27 +02:00
Julien LutranandClaude Fable 5 61e3606d33 Set Europe/Paris timezone in all nuc containers
Applied live to the 5 running containers; install scripts and the
post-install checklist now include the timedatectl step.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-08-11 00:52:05 +02:00
Julien LutranandClaude Fable 5 ee9eaee889 Initial import: nuc and ks4 infrastructure documentation
README with instance tables and nuc<->ks4 network flow chart;
per-container install/troubleshooting docs for nuc (jellyfin
server/client, transmission-bt, bare-metal reinstall) and the
ks4 two-leg backup scheme (incus-copy over wireguard).

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-08-09 22:50:07 +02:00